Mechanical Snubbers
Application:
Mechanical snubbers permit gradual thermal movements of the piping or equipment to take place virtually unrestricted. However, when a sudden dynamic event attempts to displace the piping or equipment, this dynamic restraint instantly provides a damping force proportional to the magnitude of the disturbance.
Principle of Operation:
The Fronek A/DE DynA/Damp mechanical snubber’s principle of operation is simple and straightforward. When a dynamic disturbance attempts to displace piping or equipment in either direction, an oscilatory type escapement mechanism restricts pipe movement to a constant velocity. The DynA/Damp dynamic restraint has all of the advantages of hydraulic dampening without any of the drawbacks – it is a non-locking, velocity limiting device, that is always engaged and responds to dynamic disturbances instantly.
Features:
- Corrosion-resistant materials
- 40 years of virtually maintenance-free operation
- Continuous operation at 150°F with brief transients to 350°F
- Instantaneous dynamic response
- Radiation-resistant lubrication
- Suitable for ASME Section III construction