General Dimensions & Specifications

Fronek A/DE manufactures 7 models, each with 4 configurations. The different configurations are identified by the last digit in the snubber model number. This number identifies what attachment is fastened to the fixed end of the snubber and whether the snubber or dynamic restraint can be tested for operability while installed (testable vs. non-testable). Configuration designations -0 and -1 can optionally come with a transition tube kit and pipe, which effectively lengthens the overall assembly to provide the user with a simple way of accommodating dimensional limitations between the piping and building structure.

When ordering, specify the snubber model number, description, and stroke.

 

Snubber Model Description Nominal Stroke Rated Load* Minimum Pin-to-Pin Retracted Envelope Detail Drawing
AD-40 Flanged End, Non-Testable 3″ 400 LB. 14-25/32″ PB0041425 REV. A
AD-41 Flanged End, Testable
AD-42 Paddle End, Non-Testable 9-3/8″
AD-43 Paddle End, Testable
AD-70 Flanged End, Non-Testable 4″ 700 LB. 17-3/16″ PB0041423 REV. A
AD-71 Flanged End, Testable
AD-72 Paddle End, Non-Testable 11-21/32″
AD-73 Paddle End, Testable
AD-150 Flanged End, Non-Testable 4″ 1,500 LB. 19-21/32″ PB0041424 REV. A
AD-151 Flanged End, Testable
AD-152 Paddle End, Non-Testable 13-1/8″
AD-153 Paddle End, Testable
AD-500 Flanged End, Non-Testable 4-7/8″ 5,000 LB. 24-7/8″ PB0041422 REV. A
AD-501 Flanged End, Testable
AD-502 Paddle End, Non-Testable 16-7/8″
AD-503 Paddle End, Testable
AD-1600 Flanged End, Non-Testable 6-1/8″ 16,000 LB 26-1/4″ PB0041421 REV. A
AD-1601 Flanged End, Testable
AD-1602 Paddle End, Non-Testable 19-15/32″
AD-1603 Paddle End, Testable
AD-5500 Socket End, Non-Testable 6-1/4″ 55,000 LB. 39-31/32″ PB0041426 REV. C
AD-5501 Socket End, Testable
AD-5502 Paddle End, Non-Testable 28-7/8″
AD-5503 Paddle End, Testable
AD-5500L Socket End, Non-Testable 12-1/4″ 45,000 LB 45-31-32″ PB0041436
AD-5501L Socket End, Testable
AD-5502L Paddle End, Non-Testable 34-7/8″
AD-5503L Paddle End, Testable
AD-12500 Socket End, Non-Testable 6″ 125,000 LB. 50-3/16″ PB0041427
AD-12501 Socket End, Testable
AD-12502 Paddle End, Non-Testable 37-1/8″
AD-12503 Paddle End, Testable

 

* The load rating is applicable to commercial units only. For nuclear applications, consult the applicable load capacity data sheet or design report.

Applications & Industries Served

Ammonia Plant
Chemical Plant
Clean Fuels
Commercial
Electric Plant
Energy Facility
Ethylene Plant
LLDPE Chemical Plant
LNG Plant
MTBE Plant
Natural Gas Combined Cycle Facility
Natural Gas Processing & Separation
Oil Refinery
Oil Sand Mine
Paper Manufacturer
 

Photo Gallery

 
Top